[Flash Point] >100 | |
[Fire Fighting] Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. Extinguishing media: For small fires, use dry chemical, carbon dioxide, or water spray. For large fires, use dry chemical, carbon dioxide, alcohol-resistant foam, or water spray. Cool containers with flooding quantities of water until well after fire is out. | |
[Fire Potential] Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. | |
[Ingestion] If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately. | |
[Inhalation] Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid. | |
[Skin] Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. | |
[Eyes] Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid immediately. | |
[Storage] Store in a cool, dry, well-ventilated area away from incompatible substances. Keep containers tightly closed. | |
[Handling] Wash thoroughly after handling. Use with adequate ventilation. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. | |
[Ingestion] Harmful if swallowed. May cause irritation of the digestive tract. | |
[Inhalation] Causes respiratory tract irritation. Effects of inhalation may be delayed. | |
[Skin] Causes skin irritation. Effects of contact may be delayed. | |
[Eyes] Causes eye irritation. | |
[Hazards] Contact with metals may evolve flammable hydrogen gas. | |
[EC Risk Phrase] R 25 | |
[EC Safety Phrase] S 22 45 | |
[UN (DOT)] 2811 | |
[Personal Protection] Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure. | |
[Respirators] Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary. | |
[Appearance] White crystalline powder. | |
[Solubility in water] Soluble | |
[Melting Point] 241 - 244 | |
[Density] 1.12 g/cm3 | |
[Vapor Density] 2.94 | |
[Product Name] Piperidine hydrochloride | |
[Synonyms] Hexahydropyridine hydrochloride Piperidin-1-ium chloride Piperidinium chloride | |
[CAS] "CASEN_6091-44-7.htm">6091-44-7 | |
[Formula] C5H12ClN | |
[Molecular Weight] 121.61 | |
[EINECS] 228-033-8 | |
[RTECS] TN0400000 | |
[RTECS Class] Drug | |
[Beilstein/Gmelin] 3611699 | |
[Beilstein Reference] 5-20-02-00003 | |
[EC Class] toxic | |
[Small spills/leaks] Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, using the appropriate protective equipment. Sweep up, then place into a suitable container for disposal. Provide ventilation. | |
[Disposal Code] 9 | |
[Stability] Stable under normal temperatures and pressures. | |
[Incompatibilities] Strong oxidizing agents. | |
[Decomposition] Hydrogen chloride, nitrogen oxides, carbon monoxide, carbon dioxide, nitrogen. | |
[Combustion Products] Fire may produce irritating, corrosive and/or toxic gases. | |
[UN Number] 2811 | |
[Hazard Class] 6.1 | |
[Packing Group] I; II; III | |
[HS Code] 2933 32 00 |